Panasonic air source heat pump range

The Panasonic air source heat pump range is an efficient, affordable route to low-carbon heating.

Panasonic ASHP range features

  • Quiet, with maximum sound power levels as low as 59 decibels
  • Simple, compact controller
  • Available in five sizes: 5kW, 7kW, 9kW, 12kW (twin fan) and 16kW (twin fan)
  • MCS approved for Renewable Heat Incentive applications
  • 7-year warranty when commissioned by a Nu-Heat engineer
  • Pair with our EnergyPro® cylinders for domestic hot water
  • Built-in filter and charge pump

Why choose a heat pump from Nu-Heat?

As a MCS accredited company, we know what it takes to design an efficient system that effectively heats a home, whilst also keeping running costs low.

Our systems include tailored project schematics and all system components and fittings as standard, for a quick and smooth installation that is backed up with lifetime technical support.

Why choose nu heat infographic

inforgraphic of system schematic

Which unit will I need?

We will take factors such as the size of the property, location and domestic hot water demand into account to select the right size heat pump for the project.

Technical specification

Model 5kW 7kW 9kW 12kW 16kW
CoP at 7/35 ̊C* 5.08 4.76 4.48 4.74 4.28
Power output at 7/35 ̊C (kW) 5 7 9 12 16
Operating voltage 230V
Max. outgoing heating medium temp. 60̊C 55̊C
Height with stand (mm) 865 1410
Width (mm) 1283
Depth (mm) 320
Weight (kg) 99 104 140
Max sound power level (dB(A))** 59 69 72

* In accordance with EN 14511 for heat source entry at 7 ̊C / hot water flow at 35 ̊C
** In with accordance to EN-12102

Positioning the unit

Panasonic air source heat pumps can be installed on almost any kind of terrain and are supplied in a range of sizes to heat properties of almost any size.

  • Place the heat pump unit outdoors, at ground level, on a solid level base, preferably a concrete foundation – do not place it directly on a lawn or other non-solid surface. If used, concrete slabs must rest on tarmac or gravel.
  • The position should allow for good air circulation around the unit, access for maintenance, and ensure the minimum distances to walls or obstacles are achieved.
  • The heat pump unit should not be positioned where its operation will cause inconvenience to the occupants or neighbours.
    We can help calculate this to meet MCS020.
  • Provision should be made to take condensate water to a soakaway, drain or similar.
  • Positioning should be in accordance with local planning guidance.

Energy efficiency fiche

Model 5kW 7kW 9kW 12kW 16kW

Temperature application ( ̊C)

35 55 55 35 55 35 55 35 35 55

Seasonal space heating energy efficiency class, average climate

A+++

A++

A+++

A++

A+++

A++

A++

A++

Rated heat output, average climate (kW)

5

6 7 7 8 10 8 12 13

Annual energy consumption for space heating, average climate (kWh)

2018

2849 2532 4354 2949 4971 4286 4840 5146 8076

Seasonal space heating energy efficiency, average climate (%)

202 142 193 130 193 130 190 134 190 130

Max sound power level (dB(A))

59 69 72

Rated heat output, cold climate (kW)

6 4 7 6 7 6 11 9 12 10

Rated heat output, warm climate (kW)

5 4 7 6 7 6 11 9 13 10

Annual energy consumption for space heating, cold climate (kWh)

3625 3338 4132 4967 4132 4967 6327 7147

6911

7955

Annual energy consumption for space heating, warm climate (kWh)

1113 1274 1627 1971 1627 1971 2368 2970 2801 3104

Seasonal space heating energy efficiency, cold climate (%)

160 115 164 116 164 116 168 121 168 121

Seasonal space heating energy efficiency, warm climate (%)

237 165 227 160 227 160 245 159 245 169

 